26
C
ONTROL MASTER
Edit Lock
Managed
CONTROL
MASTER
ENTER
CANCEL
VDC SLOT
RS-232
MIDI In
MIDI Out
GPIO In
GPIO Out
ASSIGN
PORT
Managed Mode allows the network to be controlled from a computer
and can only be entered from the Control Master.
To manage a Pro64 network with a PC, the PC needs to be connected
to the Control Master using a DB9 null modem cable connected to the
RS-232 port. The RS-232 baud rate DIP switches must also be set to the
same rate as the PC application.
Exiting Managed Mode is also done from the Control Master. Pressing
the lit M
ANAGED button followed by the ENTER button will return the
network to local control. Attempting to enter or exit Managed Mode
from any module other than the Control Master will cause the Managed
button LED to blink to indicate the error.
Password Protection
All Pro64 devices ship with a default password. However, a Pro64
network can be password protected from the Control Master only. Once
protected, the front-panel interface on all modules is locked, preventing
changes to A-Net Slots, sample rate, clock source, channel activation,
stereo links, and Virtual Data Cable assignments. Hardware switches,
such as gain settings on input and output modules, and rear-panel DIP
switches are in the analog domain and are not affected.
Password protection remains in force even when a system is power
cycled.
When a network is password protected, the front panel interface can be
used to get information on channel Slot assignments and VDC routings.
Pressing a channel button will display its Slot assignment in the A-Net
Slot display. Pressing the VDC inc/dec buttons will cycle through the
fourteen VDC Slots, displaying any port assignments on the current