Aviom MH10f Guía de usuario Pagina 117

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 144
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 116
105
F
IRMWARE UPDATE
device.
To enable firmware updates on the module, press FUNCTION, followed
by the CHANNEL 15 ACTIVE button. The Enter/Cancel LED and the channel
level LEDs will flash to indicate that this function will interrupt normal
network operation. Press E
NTER to enable the module to receive new
firmware from the PC host. Send the firmware update following the
instructions that came with the Pro64 Update Tool. During the update
the sixteen red, yellow and green channel meter LEDs will flash in
sequence.
When the firmware update has been sent successfully, the module will
reset and normal front panel operation will be restored. If for some
reason the firmware update fails, refer to the error recovery information
below for instructions on how to recover and complete the update.
When a module is being updated locally, the dot in the VDC Slot display
will be on, indicating that a local firmware update is in progress.
When a module is waiting for a firmware update to begin, you can exit
the firmware update state by pressing the C
ANCEL button. If the firmware
update has not yet started, the module will attempt to reset, returning it
to normal operation.
N
OTE: Do not press the CANCEL button while a firmware update is in
progress.
Error Recovery
In case of a partial firmware download or interruption to the firmware
transfer (as would happen because of a power failure, computer crash,
or by pressing the Cancel button in the middle of a firmware update), the
module can still be updated but will need to be powered up directly into
the firmware load mode. To do this, hold the VDC Slot decrement (down
arrow) button while powering up the unit. Then send the firmware from
the computer as described previously.
Firmware Update - via A-Net
To enable a Pro64 module to receive new firmware via A-Net on an active
network, the PC must be connected to the RS-232 port on the Control
Master. The network must be in Managed Mode to update firmware via
A-Net. All network audio will be muted, and front-panel functions will
be disabled on the module being updated.
To enable firmware updates, a module must be selected from within the
Pro64 Update Tool application, at which point it will be set up to receive
new firmware. Send the firmware update following the instructions that
Vista de pagina 116